DFC can now label its products with the CE Mark |
||
Dynamic's flow computers has passed the Electromagnetic Compatibility test required to be in compliance with the European EMC Directive (89/336/EEC). |
||
| Our flow computers were tested utilizing the following documents and found to be in compliance with the required criteria on the indicated test dates. EN 61326-1: A1:1998 and A2: 2001 Radiated Emissions Class A October 4, 2004 EN 61000-4-2: 1995 4/8kV October 5, 2004 EN 61000-4-3 A1:2002 10 V/m September 30, 2004 EN 61000-4-4: 1995 .5/1kV September 29, 2004 EN 61000-4-6: 1996 3 Vrms October 5, 2004 EN 61000-4-8: 1994 30 A/m October 5, 2004 |
||
Tests carried out: Electromagnetic Emissions Testing Electromagnetic Immunity Testing Electrostatic Discharge Testing Radiated Immunity Testing Electrical Fast Transient Testing Conducted Immunity |
||