| MICROMG4 Image Release History | ||||
| Version | Release Date | Changes | ||
| 6.00.1 | 6/12/2001 | 1. Correction - RTD Reading (Increase RTD Gain) | ||
| 2. Correction - Month Total | ||||
| 6.01.0 | 7/22/2001 | 1. Add V-Cone Calculation | ||
| 2. Correction - Analog Output | ||||
| 3. Freeze Display Through "Enter" Scan Key | ||||
| 6.01.1 | 8/1/2001 | 1. Correction - Default to Metric Unit | ||
| 6.01.2 | 8/20/2001 | 1. Add New Modbus Registers - Daily Report - Date and Time (Floating Point) | ||
| 2. Revise Communication Routine | ||||
| 6.01.3 | 9/18/2001 | 1. Correction - Spare Data (Front Panel Display) | ||
| 6.02.0 | 9/25/2001 | 1. Change Daily Totalizer Resolution (One Decimal) | ||
| 6.02.1 | 10/2/2001 | 1. Add Modbus Poll Exceptions (7000s) | ||
| 2. Add New Modbus Registers - Hour and Day Flow Time … | ||||
| 6.02.2 | 10/17/2001 | 1. Correction - RTD Calibration | ||
| 6.02.3 | 11/26/2001 | 1. Add MPU-1200 Flow Equation (US Unit) | ||
| 6.02.4 | 11/30/2001 | 1. Correction - AGA8 - SG Range | ||
| 6.02.5 | 1/24/2002 | 1. Revise AGA8 Routine | ||
| 6.02.6 | 2/25/2002 | 1. Add MPU-1200 Flow Equation (Metric Unit) | ||
| 6.03.0 | 3/4/2002 | 1. Add Metric DP Unit Selection - m.BAR, KPA | ||
| 2. Add Metric Pressure Unit Selection - Bar, KG/CM2, KPA | ||||
| 3. Correction - Totalizer (More Resolution) | ||||
| 6.03.1 | 3/15/2002 | 1. Add New Data Entry - Venturi C Factor | ||
| 6.03.2 | 3/22/2002 | 1. Poll Slave Unit and Gas Chromatograph Through the Second RS-485 Port | ||
| 6.03.3 | 4/1/2002 | 1. Correction - Polling Gas Chromatograph Routine | ||
| 6.03.4 | 4/20/2002 | 1. Stack DP Assignment Can Be Analog Input. | ||
| 2. Modbus Shift Registers - 7001-7900 | ||||
| 6.03.5 | 7/1/2002 | 1. Set Wait State to 2 | ||
| 6.03.6 | 7/15/2002 | 1. Add New Modbus Registers - 7971 ( 2 Registers Per Variable) | ||
| 6.03.7 | 8/7/2002 | 1. Correction - Analog Input Jumping | ||
| 6.03.8 | 9/6/2002 | 1. Increase DP Range of Multi-Variable to 1075 | ||
| 6.03.9 | 10/25/2002 | 1. Add New Modbus Registers - Spare Data #1, #2, #3, and #4 | ||
| 6.04.0 | 3/14/2003 | 1. Add MPU-1200 Series B. Interface | ||
| 6.04.1 | 10/27/2003 | 1. Set ROM/RAM Wait State to 1 | ||
| 2. Reset the Device if Multivariable Communication is Lost | ||||
| 6.04.2 | 5/20/2004 | 1. Correction - Broadcast Command | ||
| 6.04.3 | 6/8/2004 | 1. Set ROM Wait State to 2 | ||
| 2. Add V-Cone Calculation - Wafer/Cone Y factor Selection | ||||
| 3. Correction - Gas Chromatograph Composition Percentage Checking Routine | ||||
| 6.04.4 | 10/14/2004 | 1. Synchronize System Clock and Real Time Clock | ||
| 6.04.5 | 1/25/2005 | 1. Add - Enable/Disable Front Panel Scan Keys | ||
| 6.04.6 | 1/9/2007 | 1. Modify Display Sensitivity Key Routine | ||