EChart Suite Release History
Note: Comments in black mean new features and red changes mean corrections from previous versions.
Version Release Date   Changes
       
2.09 6/2/2008 Added support for E-LiteEXP 3095 emulation.
       
2.08 2/14/2008 Elite-EXP Diagnostic page was showing the wrong Input Tags
  E-Plus not downloading ISO-5167-2003 Parameters page
       
2.07 1/21/2008 Added support for Program Variables in the historical reports
       
2.06 1/7/2008 Added ISO5167-2003 Equation with Russian GOST Factors
  Stop Autodetect if unable to open port
  Apply DTR/RTS/CTS settings when Autodetecting
       
2.05 8/21/2007 New Verification/Calibration screen for easier/faster use
  Calibration shortcut on verification screen
  Confirmation of active communication before downloading reports
  Validate reports request by user to avoid exceeding the maximum reports allowed
  Added Firmware Downloaded V.2
  Added Firmware version selection on Display Assignments
  Downloads port configuration last so there is no disconnection in the middle of full download
  Data Verification on E-Lite not updating temperature readings
  Data Verification on E-Plus not updating live readings
       
2.04 6/8/2007 Able to cancel a calibration if user hasn't enter the first point
  Verify Reports folder is valid before collecting reports
  Ability to Calibrate & Verify RTD inputs in °F and °C besides Ohms
  Relocate Temp file to the templates folder to make app Windows Vista Compatible
  Added Page Breaks on reports so each report prints in its own page
  V-Cone: Pipe & Cone thermal expansion coeff. were backwards
  Data Verification for E-Lite was not reading analog input
  Corrected Auxiliary K Factor Volume Units shown on data entry.
       
2.03 3/19/2007 Program was not adding .SFC extension to config files when switching flow comp. types
  Prevent user from setting RS485 port on E-Lite hardware
       
2.02 1/30/2007 Was Unable to activate Bluetooth port on Echart
  Data Verification for Multivariable Inputs not updating live values
  Removed Slow Pulse application on EliteEXP
  Added additional Application Tag Checking for Modem communications
  Added wiring drawing for 3 wire RTD on E-Lite Model
       
2.01 12/15/2006 Added Support for E-Lite EXP Flow Computer
  Added CF and M3 units for E-lite
       
2.00 7/1/2006 SUPPORT FOR ECHART, E_PLUS & E_LITE IN A SINGLE APPLICATION
   
  Additional Features since the Individual EChart Program:
  Customized Historical Database for Echart and E-Lite
  CFX Report data in Absolute pressure to prevent Flow-Cal recalculation.
  CFX Report History type is now 1 so Flow-Cal gets analysis data from snapshot data.
  Support for Bluetooth Port Configuration.
  Direct Manipulation of Report generation for Faster Formatting.
  Removed Database and duplicated code for data capture improved speed.
  Status Bar now shows detailed report capture progress.
  Composition Screen has chemical formulas in addition to component names
  Autodetect feature can be cancelled
  AGA8 Method 1 & 2 was not downloading in previous applications