| MicroMS4 Release History | ||||
| Note: Changes in black mean new features. Changes in red mean corrections from previous versions. | ||||
| Version | Release Date | Changes | ||
| 2.11 | 6/27/2007 | Add support for Gravity and Base Density Factors | ||
| Corrected Monthly report support for flow time in minutes | ||||
| 2.10 | 3/21/2007 | Not displaying February's 28 days on monthly reports | ||
| 2.9 | 1/30/2007 | Reports skipping records when reports not starting on the last record | ||
| 2.8 | 1/29/2007 | Ability to disable Program Variable Statements Validation | ||
| BSW Factor was not being displayed on Daily Report | ||||
| Reports not showing right records if reports not starting on the last record | ||||
| Updates to Reports: | ||||
| Snapshot report - Increased decimals of gas components to 4 decimals. | ||||
| Added units to all the heading info | ||||
| Hides DP information when using frequency meters | ||||
| Provides option to show flow time in either hours or minutes | ||||
| 2.7 | 7/21/2006 | Added Support for Live BS&W input | ||
| 2.6 | 8/14/2005 | Data Verification screens was not updating live readings | ||
| Calibration & Verification report rounding Atmospheric pressure value | ||||
| 2.5 | 5/16/2005 | Corrected Program Variable Validation (did not allow for display variables) | ||
| 2.4 | 3/16/2005 | Added Daylight Saving Time (DST) | ||
| Validate Config File Schema to prevent opening wrong file types | ||||
| 2.3 | 2/11/2005 | Added Additional flow control for modem connection | ||
| Increased Meter Test Report Resolution | ||||
| 2.2 | 2/10/2005 | Added RTS/CTS/DTR Flow Control | ||
| 2.1 | 12/9/2004 | New Turbine Diagnostic Feature | ||
| Saves Calibration in configuration file | ||||
| Dial Up (Modem) Communications | ||||
| 2.0 | 10/15/2004 | Added new Audit Trail Codes for Analog Inputs | ||
| Added Units to Flow Rate High/Low Limits | ||||
| Diagnostic Screen not showing Analog Out RTD Assignment Text | ||||
| 1.0.0.18 | 9/3/2004 | Support for Meter composition selection from other meter runs. | ||
| Modbus Driver includes Auto Type and stores las values used. | ||||
| 1.0.0.17 | 7/25/2004 | Allow Switch Output to be used in Boolean Statements (2751-2753) | ||
| Problem with PID Drop-down menu (some actions do not work) | ||||
| Added Battery Voltage readings and alarms | ||||
| Upgraded program variables to accept negative numbers | ||||
| Unable to clear Floating Modbus shift | ||||
| 1.0.0.16 | 2/29/2004 | Version 1.0.0.15 had problem Loosing Data entries due to changes in combo boxes | ||
| Re-enable Switch # 4 - MicroMS4 is the only MicroMV that supports Switch 4 | ||||
| Added Last 10 Samples to Leak Detection Test and corrected decimal places on report | ||||
| 1.0.0.15 | 1/26/2004 | Disabled Switch # 4 for user selection | ||
| Added additional wait time to improve communications | ||||
| Disable parity selection for RTU Modbus mode | ||||
| 1.0.0.14 | 11/25/2003 | Able to poll floating registers with different HI/LO and byte length configurations. | ||
| Add Spare Assignment (Number 1) in status inputs. | ||||
| Add Modbus Driver Window | ||||
| Added Custom Flow Units, so customer can add its own units to the reports. | ||||
| Venturi C Override had wrong decimal places | ||||
| Override values were being clear when downloading the configuration | ||||
| Enable analog input expansion without having to configure slave units | ||||
| 1.0.0.13 | 9/8/2003 | Add Third Frequency Input Selection in AGA7 | ||
| Add V-Cone Pipe and Cone thermal coefficients | ||||
| Change Calibration Windows for a more user-friendly way | ||||
| 1.0.0.12 | 7/11/2003 | Add Liquid Correction at 20°C | ||
| 1.0.0.11 | 5/9/2003 | Add Calibration and Verification Report | ||
| Add Copy of PC Time to FC time with a button | ||||
| Image Download Window Upgrade | ||||
| Ability to configure Meter Well Test Offline | ||||
| Tank Leak Test - Database and data adquisition revision | ||||
| Do Not Allow 0 as Modbus ID | ||||
| Change Location of Gas Chromatograph Window to main menu | ||||
| Removed Station Total Selection (This feature is not available) | ||||
| 1.0.0.10 | 4/14/2003 | Added Leak Detection Application | ||
| Moved SG/API entry to Meter Data Menu (For Liquid Applications) | ||||
| 1.0.0.9 | 2/25/2003 | Allowed Atmospheric Pressure in KPAs to be above 100 | ||
| Added Multithreading Communications - Improved serial and Ethernet response | ||||
| Slave units configuration screens revised | ||||
| Liquid Application in Barrels or Cubic Meters supported. | ||||
| Supports TCP/IP Communications besides ModbusTCP | ||||
| Meter Data and Others Settings windows were rearranged | ||||
| 1.0.0.8 | 1/22/2003 | Exporting Configuration to Text File Capability | ||
| Help Information Update for Slave Units and Chromatograph | ||||
| Added Floating Point Mode (2/4 Bytes and (HI/LO) or (LO/HI) Mode support) | ||||
| 1.0.0.7 | 12/19/2002 | Supports mass flow Foxboro meters as slaves | ||
| Supports different flow units for each Meter | ||||
| Supports Gas and Liquid Meters in the same unit | ||||
| Was unable to change Analog Output ranges. | ||||
| Corrected Hourly Report - Split hours by day | ||||
| Added ability to download image files to applications other than MicroMS4 | ||||
| 1.0.0.6 | 11/25/2002 | Able to configure Slave Communications being Offline | ||
| Able to configure Chromatograph Offline | ||||
| Added Rx, Tx communication indicators | ||||
| AGA8 Detailed Entry recalculates total percentage automatically. | ||||
| Typo in AGA8 Detailed Method components | ||||
| 1.0.0.5 | 11/6/2002 | Was Unable to Calibrate in Full Span (Two-point Calibration) | ||
| 1.0.0.4 | 10/18/2002 | Modified Meter Test to suit for Customer Needs.(Meter Testing new features). | ||
| 1.0.0.3 | 10/14/2002 | Changed Crystal Report Engine Program to improve reliability | ||
| Was showing Override Stars for disable Meters | ||||
| Found Problem with the Snapshot variable definition causing memory problems | ||||
| Solved Crystal Reports Engine Issue | ||||
| Added Units to the Last Month Report | ||||
| Did not show Atm. Pressure and ID units accordingly with units system (metric/us) | ||||
| Added Spare Input values in Snapshot report | ||||
| Added Program Variables Statements and Tags | ||||
| 1.0.0.2 | 9/12/2002 | First Full Release. | ||
| 1.0.0.1 | 8/1/2002 | Start working in the Application | ||
| Beta Version | ||||