| MicroMG4
handles up to four gas meters using the master-slave ports and multiple
primary elements. Primary elements include ultrasonic, turbine,
orifice, venture, and V-Cone, etc. This flow computer can be set
in Us or Metric standards. |
| File |
Version
|
Description |
| |
MicroMG4 |
6.03.7 |
MicroMV
- 4 Gas Meters application. |
| |
| |
| MicroMVG
is used for gas in US units to handle different kinds of primary
elements and gases. This is a dual meter run gas flow computer.
It allows products such as natural gas using AGA3 and AGA8 methods.
Steam, saturated steam, and all commercial gases including oxygen,
hydrogen, nitrogen, helium and ethylene can be used with this flow
computer. |
| File |
Version
|
Description |
| |
MicroMVG |
6.03.2 |
MicroMV
- 2 Gas Meters |
| |
MicroMV5 |
6.02.1 |
MicroMV
- Gas Meter with Enron Modbus |
| |
| |
| MicroMVA
is used with US units for commercial gases with four levels of premium
billing provided. It is a dual meter run flow computer with stack
DP functions. |
| File |
Version
|
Description |
| |
MicroMVA |
6.02.4 |
MicroMV
- Air and gas Meter with premium billing |
| |
| |
| MicroMVL
is used with US units to cover liquid applications. This is a dual
meter general purpose flow computer that has differential and frequency
type input but without meter proving. It can be used for custody
measurement for crude, refined products, LPG, ethylene, propylene,
and PPMix (Propane-Propylene mix). It is similar to the SFC332L,
however it also includes the touch screen feature and a wider display. |
| File |
Version
|
Description |
| |
MicroMVL |
6.03.0 |
MicroMV
- 2 Liquid Meters |
| |
|
|
| SFC332
Applications |
| How
do I know if I have big or small EPROMs on a SFC332 unit? |
| |
| SFC332L
is used for liquid applications for orifice, turbine, and in petrochemicals
and refining industries. It supports both US and Metric standards.
This is a dual meter run general purpose flow computer that has
differential and frequency type input but without meter proving.
It can be used for custody measurement of crude, refined products,
LPG (Liquified Petroleum Gas), ethylene, propylene, and PPmix (Propane
Propylene Mix). It has complete audit trail, alarm log, and all
the API requirements to meet API 21.2 for liquid EFM. |
| File |
Version
|
Description |
| |
SFC332L |
1.32.1 |
SFC332
Liquid Application for 2 meter runs. (Regular Application) |
| |
SFC332L
Small EPROM |
1.24.4 |
Same
as SFC332L for small EPROMs Hardware.Do
you have big or small EPROMs? |
| |
SFC332L
Metric |
1.04.3 |
Same
as SFC332L but uses Metric Units standard. |
| |
| |
| SFC332
is used for all varieties of liquid pipeline applications. These
meters can be set in US or metric standards. This is a dual meter
run liquid flow computer with meter proving functionality. It can
handle all crudes, refined products, and LPG. Prover can be used
with double chronometry or standard method. There are several standard
functions in this particular flow computer such as pulse output
to the sampler, prover valve controls, batching, product interface,
and density inputs. Turbine diagnostic is also available for early
detecting of turbine meter problems. |
| File |
Version
|
Description |
| |
SFC332
v.3 |
3.11.2 |
SFC332
Liquid Pulse Version 3 (Regular Application) |
| |
SFC332
Metric |
1.05.1 |
SFC332
Liquid Pulse Metric Units Version |
| |
SFC332W |
1.04.2 |
SFC332
Water Application |
| |
| |
| SFC332G
is used for a variety of pipeline and plant applications for gases.
It includes different types of primary elements, such as orifice,
turbine, venturi, annubar, and V-Cone. It support Us and Metric
systems. This is a dual meter run gas flow computer. It allows products
such as natural gas using AGA3 and AGA8 methods. Steam, saturated
steam, all commercial gases including oxigen, hydrogen, nitrogen,
helium, and ethylene can be used with this flow computer. The density
can be calculated using NBS for steam and commercial gases. In addition
AGA8 can be used for commercial gases. A densitometer is accepted
for process gas applications where composition is changing. |
| File |
Version
|
Description |
| |
SFC332G
v.1 |
1.33.9 |
SFC332G
Regular Gas Application. |
| |
SFC332G
v.3 |
3.08.5 |
SFC332G
Gas with Gas Chromatograph capabilities. |
| |
SFC332G
v.5 |
5.13.2 |
SFC332G
Gas Application with Enron Modbus protocol. |
| |
SFC332G
v.1 Small |
1.32.3 |
SFC332G
Regular Gas Application using Small EPROMs. How
do I know if I have big or small EPROMs? |
| |
SFC332G
Metric |
1.14.3 |
SFC332G
Metric Units System |
| |
| |
| SFC332P
is used strictly for meter proving for up to 60 meters. The SFC332P
flow computer can be used with US or Metric standards. It can be
used in a mobile type prover or a stationary prover proving multiple
meter runs. The SFC332P can be ple-configured with up to 60 meters
with complete information associated with location, lease and lact
names. Crude, refined products and LPG can also be configured. |
| File |
Version
|
Description |
| |
SFC332P |
1.13.11 |
SFC332
Prover - US Units System |
| |
SFC332P
Metric |
1.15.6 |
SFC332
Prover - Metric Units System |
| |
| |
| SFC332T
is used for test separators. This flow computer can only be set
with US standards. The SFC332T measures oil, gas and water and measures
the ratio of each in the mixture. It requires two turbine/PD for
oil and water and one gas meter run. This flow computer allows up
to 8 wells to be pre-configured in each computer. It also gives
complete test report that meets API 20.2 requirements. Continuous
measurement is possible but the SFC332T's primary function is as
a test separator. |
| File |
Version
|
Description |
| |
SFC332T |
1.04.8 |
SFC332
& E-Plus Test Separator Application |
| |
| |
| SFC3
can handle up to three bi-directional meters. It is used for liquid
pipeline and proving in US units only. Can use up to four meter
runs or three bi-directional meters with densitometer. Crude refined
products and LPG can be configured. |
| File |
Version
|
Description |
| |
SFC3 |
1.10.3 |
SFC3
- 4 Frequency Inputs |
| |
| SFC5000
Applications |
|
|
| |
| SFC5000
Panel mount flow computer is used for pipeline and meter proving
and can handle up to three meter runs. It perform meter proving,
batching, and density interface. The design applies only for Liquid
and US Standards. Products include crude refined products and LPG.
Turbine and PD meters are allowed as primary elements. |
| File |
Version
|
Description |
| |
SFC5000
Liquid Pulse |
5.02.1 |
SFC5000
Liquid Pulse Application |
| |
| |
| SFC5000L
panel mount is used for liquids without meter proving for dual meter
runs. It utilizes primary elements such as turbine, orifice, venturi,
mass meters and others. This flow computer handles products like
crude oil refined products, LPG, ethylene, and propylene. US and
Metric standard can both be set in this flow computer. |
| File |
Version
|
Description |
| |
SFC5000L |
5.05.5 |
SFC5000L
Liquid Application |
| |
SFC5000L
Metric |
5.09.2 |
Same
as SFC5000L Liquid application using Metric Units |
| |
| |
| SFC5000G
can be used for gases and can be configured with US or metric units.
It has independent dual meter runs with different primary elements,
which include turbine, orifice, venturi, V-Cone, etc. This flow
computer handles products such as natural gas, steam, and commercial
gases. |
| File |
Version
|
Description |
| |
SFC5000
Gas |
5.02.3 |
SFC5000
Gas Application |
| |
Customized
DOS Applications |
| File |
Version |
Description |
| SFC332GM |
1.13.1 |
SFC332
Gas - Algeria Project |
| SFC332L
CIS |
1.23 |
SFC332
Liquid - CIS Project |
| SFC3
Williams |
1.10.8 |
SFC3
- Williams Pipeline Project |
| SFC332
v.2 |
2.23.0 |
SFC332
Version 2. (Provided only for backward compatibility with version
2 systems). |
| SFC332
v.1 |
1.19.0 |
SFC332
Version 1. (Provided only for backward compatibility with version
1 systems). |