SFC 332P Prover Computer


The field mounted prover controller SFC332P offers not only exceptional accuracy, but substantial cost savings as well. It has recently been perfected to include on-line turbine diagnostics. Its design, in a NEMA 4X explosion-proof housing, offers some of the following features and advantage.
  • Supports Metric and Imperial (US) Units.
  • Supports both Stationary and Portable prover systems.
  • For portable prover you can pre-configure up to 60 meters.
  • Can use dual or single detector swtiches.
  • Uses Pulse Interpolation (Dual Chronometry) for Small Volume Provers (SVP).
  • Provides support for 4-way valve control.
  • Eliminates miles of field wiring during installation and the signal deterioration this generates.
  • Easy installation, commissioning and maintenance
  • Low power requirements
  • Highest accuracy - signal and stability
  • Full compliance with API, AGA and ISO standards
  • Serial link outputs for batching, reporting, proving, etc.
  • Ideal replacement for panel mount flow computers
SFC Flow Computer Specifications
Processor 32-BIT Motorola 168332 @ 16.7 MHz
Memory RAM 2 MB @ 30 Nanoseconds
  FLASH ROM 4 MB @ 70 Nanoseocnds
 Power Voltage Range 12-30 VDC
  4 Watts
Operating Conditions
Temperature - 40 TO 185 °F
  Humity 100%
  Housing NEMA 4X CLASS 1 DIV. 1
Inputs/Outputs LCD Display 2 Lines 16 Characters
  3 FREQUENCY INPUT CHANNELS EXPANDABLE TO 4
Frequency Range : 0 - 5000 Hz
With Turbine Diagnostic Function
>70 mV for Sine Wave
> 6 Volts for Square Wave
  4 Analog Input 24-Bit Channels expandable to 8
  2 RTD Input Channels 4 Wires 100Ohm Platinum
  2 Analog Output Channels 12 Bit Single Ended
  2 Detector Switches for Prover Run detection
  5 Digital Output (Outs 1 & 2 are Pulse/Switch 0.5 Amps Rating, Outs 3 to 5 are Switch Outputs 0.25 Amps Rating).
  4 Status Inputs ON/OFF Type signal
  All Inputs and Outputs are Optically Isolated>
Communications 1 Serial RS485 @ 38400 Bauds max.
  1 Serial RS232 @ 19200 Bauds max.
  MODBUS™ Communication Protocol
Measurement Free Modbus™-driven configuration software included
  Multiple API, AGA and ISO equations and calculation algorithms are programmed.
  Uni- or bi-directional runs
  Generates prover report automatically.